Complex data formats
DICOM-RT objects such as RTPlan and RTStructureSet contain deeply nested sequences and references between objects. Without knowing the structure, it is easy to extract wrong or incomplete data.
Medical software leaves little room for error: data must be processed correctly, workflows must be unambiguous for clinical staff and every change must be traceable. I combine modern web development with Angular and C# .NET with hands-on experience from developing radiation therapy software at LAP Laser.
In a MedTech team it isn't enough for a feature to work technically. Developers need to understand medical data formats, think through clinical workflows and cope with the demands of a regulated development process – otherwise every feature turns into a long feedback loop.
DICOM-RT objects such as RTPlan and RTStructureSet contain deeply nested sequences and references between objects. Without knowing the structure, it is easy to extract wrong or incomplete data.
An interface that seems logical to developers doesn't automatically fit the workflow in the treatment room. A lack of closeness to the workflow shows up in usability testing at the latest.
Requirements traceability, validation and defined quality requirements demand discipline in day-to-day development – not just shortly before an audit.
Medical systems need to work together with hardware, existing systems and standards such as DICOM and HL7 FHIR. Interfaces quickly become the bottleneck.
Extraction and processing of data from DICOM-RT objects – specifically RTStructureSet and RTPlan – and their integration into clinical software workflows for surface-guided radiation therapy (SGRT) at LAP Laser.
Encrypted communication with medical hardware (linear accelerators, LINAC) in clinical environments – also part of the SGRT project at LAP Laser.
Designing and building interfaces for clinical workflows – including the requirements of FDA usability testing.
Development according to IEC 62304 (software life cycle) and IEC 62366-1 (usability engineering) with traceability, validation and quality requirements.
€1,999/month
MedTech projects usually run over a longer period. A retainer gives your team predictable capacity; larger allocations or a clearly scoped project can be discussed individually.
Mr Birke was instrumental in the design, development, and stabilisation of our system. In collaboration, Mr Birke demonstrated a very reliable, independent, and transparent working style. I recommend Fabian Birke unreservedly for MedTech and HealthTech projects.
His contributions to practical UI/UX designs were of central importance, particularly during the usability testing phase as part of the FDA approval.
With DICOM-RT objects, specifically RTStructureSet and RTPlan: I have extracted and processed data from them and integrated it into clinical radiation therapy software workflows.
Yes. I have designed and built interfaces for clinical workflows that had to meet the requirements of usability testing as part of an FDA approval.
Yes. As a developer I have worked according to IEC 62304 (medical device software life cycle processes) and IEC 62366-1 (usability engineering for medical devices).